volume flows from 600
m³/h to 120.000 m³/h. Differential pressures between 7 and 12 bar are
standard at single-stage compression. With multi-stage design discharge
pressures of 25 bar and 40 bar max., but also vacuums lower Pe –0,9 bar
are achieved. The maximum (1350 mm) and the minimum rotor length (155 mm)
give an impression of the entire breadth of the offer. For the adjustment to
the different process gases, rotors made of steel or special steel and casing
of nodular cast iron, steel- or special steel casting can be
applied.
The unit design can be effected acc. to
the following guidelines:
- DIN / EURO standards
- NACE
- AD-regulations
- TEMA - standard
- ASME VIII Div. 1, incl. U-stamp
- API-guidelines
|